Example: Enabling a Multiplexer
The following example shows how to use the Store Default System Parameter
command with the data value of 0x02 to enable the multiplexer. (The example
shows both ASCII and binary forms of the command.)
Command = Store Default System Parameter
Mandatory Flags = Data
Request (ASCII Mode)
Start Flags Command Address Number Blocks Data Length Data CRC End
<CR> 0x0820 0x1301 0x000A 0x0001 0x0001 0x02 0xB74C <CR>
Start Message Length Flags Command Address # Blocks Data Length Data CRC
<02> 0x000D 0x0820 0x1301 0x000A 0x0001 0x0001 0x02 0x3D83
Request (Binary Mode)
Response (ASCII Mode)
Start Response CRC End
<LF> 0x1301 0xAE70 <CR><LF>
Start Message Length Response Code CRC
<02> 0x0004 0x1301 0xCD11
Response (Binary Mode)