Quick Start Procedure
The following instructions provide an example of how to set up your new
SkyePlus multiplexer and switch between two antennas.
1. Connect your SkyePlus MXH or MXU to a host interface board with an
attached SkyeModule reader (see
‘‘Hardware Configuration’’ on page 21),
using the included control and RF cables.
2. Connect one antenna to port 0 (P0) and another antenna to port 7 (P7) of
the MXH or MXU. (Alternatively, you can connect only one antenna to port
0 and manually change it to port 7 when you instruct the MXH or MXU to
switch between the ports as described in this procedure.)
3. Use the SkyeWare software to prepare to send commands to the reader:
a. Let SkyeWare automatically discover the reader.
b. Select the Capabilities tab and then the Protocol subtab. (The
commands in the remainder of this procedure follow the more
detailed examples in the SkyeTek Development Kit User Guide.)
4. Enable the MXH or MXU with the following command:
Command: Store Default System Parameter
Address: 000A (multiplexer control)
Block: 01
Data: 02
5. Verify that the multiplexer is properly detected:
Command: Read System Parameter
Address: 000A (multiplexer control)
Block: 01
Data: The command response returns data showing the
type of multiplexer (see
Table 4-2 on page 29).
6. Set the multiplexer to port 0:
Command: Write System Parameter
Address: 000A (multiplexer control)
Block: 01
Data: 00
7. Hold a tag in front of the antenna connected to port 0.
8. Select a tag:
Command: Select Tag
Tag Type: Auto Detect
The tag should be detected successfully via port 0.
9. Reset the port to port 7:
Command: Write System Parameter
Address: 000A (multiplexer control)
Block: 01
Data: 07