AURATON 2005 / 2005 TX USER MANUAL PP LARS 2003
Thank you for purchasing the AURATON 2005. Your new programable thermostat will serve your family for years and significantly save the energy cost. The large multi-data liquid crystal display allows you to operate the feature-rich design with a touch of a button. Before operating the thermostat, we hope you can read this manual thoroughly.
INSTALLATION INSTRUCTIONS Caution: Switch off the electric source before installing the thermostat. We recommend that the installation should be performed by a trained personnel. Select a suitable location for the AURATON. The location of the thermostat can greatly affect its performance. If it is located at where circulate air cannot reach, or exposed to direct sun light, it will not adjust the room temperature properly.
FAMILIAR WITH YOUR AURATON 2005 Appearance. There is a sliding door at the right of the thermostat. If you open the door, you can see some buttons. This door is removable for the replacement of batteries. To rise up the sliding door, you can see the dip switch. Temperature mode. You can see and on both the buttons and the LCD. means comfort temperature and means economy temperature. These two temperatures are user changeable.
LCD 1) Day of the week Indicator 2) Time 3) Temperature 4) Program Number 5) Program Profile Indicator 6) Manual Override Indicator 7) Output-On Indicator and temperature Mode Indicator 8) Low Battery Indicator Note: A. The output-on indicator will be displayed if the output is on. It will disappear if the output is off. B. The low battery indicator will be displayed if the voltage of the batteries drop to a certain level. Please change the batteries as soon as possible. Start.
View/Change temperature. Press Temp, the thermostat enter View/Change temperature mode. The LCD will show the setting of the current temperature mode ( , or ) which will be flashing. Press button or button to review or change the temperature. Press OK will directly return to normal operation mode. Note: A. The temperature setting range is 5 to 30°C. B. To lower the setting, enter View/Change temperature mode and press or until it reaches 30°C and then the setting will return to 5°C.
selected, it will turn off the system). Program 1,2, and 3 are some typical schedule of a day. You can select them if you found them suitable. Program 4 set the whole day to comfort temperature while program 5 set it to economy. Program 6, 7 and 8 are user-define programs. They can be modified to suit your need. Example: A. Assume you want to assign program 6 to Saturday and want to set the whole day to economy temperature except 13:00 to 18:00. Press Prog.
HOW TO CONNECT AURATON 2005 D1. How to connect AURATON 2005 directly to a heating device. D2. How to connect AURATON 2005 to single-phase heating device with working load exceeding 5A thought magnetoelectric relay.
D3. How to connect AURATON 2005 to three-phase heating device through three-phase contactor. D4. How to connect AURATON 2005 directly to gas water heating device powered by ~220V and equipped with circulating pump.
AURATON 2005 TX Programmable Temperature Controller AURATON 2005 TX is almost the same product as AURATON 2005. The only difference is way of transmitting on/off signal. AURATON 2005 TX uses radio waves. That eliminates wires between AURATON 2005 TX and controlled device. Receiver of radio waves is module called AURATON RX. Range of AURATON 2005 TX is very high but depends on materials that house is made of.
SPECIFICATION AURATON 2005 / 2005 TX Temperature measurement 0-34.75 °C (0.25°C step) range: Temperature control range: 5-30°C (0.25°C step) Temperature accuracy: +/- 1°C Clock accuracy: +/- 70 seconds/month Program: 6 preset, 3 user-define Switching span: 0,5°C or 1°C Control mode: Heating or Cooling system Minimum air-con.