Specification

Refer to attached safety data sheets and/or instructions for use. Stop leak if you can do so without
risk. Move the cylinder to a safe and open area if the leak is irreparable. Isolate area until gas has
dispersed. Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area).
Keep combustibles (wood, paper, oil, etc.) away from spilled material. Prevent product from
entering drains. Cover with plastic sheet to prevent spreading. Absorb in vermiculite, dry sand or
earth and place into containers.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination. For waste disposal, see section 13 of the SDS.
Methods and materials for
containment and cleaning up
Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all
environmental releases. Prevent further leakage or spillage if safe to do so. Avoid discharge into
drains, water courses or onto the ground. Use appropriate containment to avoid environmental
contamination.
Environmental precautions
7. Handling and storage
Minimize fire risks from flammable and combustible materials (including combustible dust and
static accumulating liquids) or dangerous reactions with incompatible materials. Handling
operations that can promote accumulation of static charges include but are not limited to: mixing,
filtering, pumping at high flow rates, splash filling, creating mists or sprays, tank and container
filling, tank cleaning, sampling, gauging, switch loading, vacuum truck operations. Pressurized
container: Do not pierce or burn, even after use. Do not use if spray button is missing or defective.
Do not spray on a naked flame or any other incandescent material. Do not smoke while using or
until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to
heat, flame, sparks, or other sources of ignition. All equipment used when handling the product
must be grounded. Do not re-use empty containers. Avoid breathing gas. Avoid contact with eyes.
Avoid prolonged exposure. Use only in well-ventilated areas. Wear appropriate personal protective
equipment. Avoid release to the environment. Observe good industrial hygiene practices.
Precautions for safe handling
Level 2 Aerosol.
Store locked up. Pressurized container. Protect from sunlight and do not expose to temperatures
exceeding 50°C/122 °F. Do not puncture, incinerate or crush. Do not handle or store near an open
flame, heat or other sources of ignition. This material can accumulate static charge which may
cause spark and become an ignition source. Avoid spark promoters. Ground/bond container and
equipment. These alone may be insufficient to remove static electricity. Store away from
incompatible materials (see Section 10 of the SDS).
Conditions for safe storage,
including any incompatibilities
8. Exposure controls/personal protection
Occupational exposure limits
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
ValueComponents Type
PEL 2400 mg/m3Acetone (CAS 67-64-1)
1000 ppm
PEL 610 mg/m3Methyl Acetate (CAS
79-20-9)
200 ppm
PEL 2000 mg/m3n-Heptane (CAS 142-82-5)
500 ppm
PEL 1800 mg/m3Propane (CAS 74-98-6)
1000 ppm
US. ACGIH Threshold Limit Values
ValueComponents Type
STEL 500 ppmAcetone (CAS 67-64-1)
TWA 250 ppm
STEL 1000 ppmButane (CAS 106-97-8)
STEL 250 ppmMethyl Acetate (CAS
79-20-9)
TWA 200 ppm
STEL 500 ppmn-Heptane (CAS 142-82-5)
TWA 400 ppm
US. NIOSH: Pocket Guide to Chemical Hazards
ValueComponents Type
TWA 590 mg/m3Acetone (CAS 67-64-1)
3 / 11
Product name: FPAAURFOAMTK Foamtak Liquid Spray
Product #: 1000035253 Version #: 01 Issue date: 08-25-2017
SDS US