Technical data

Table Of Contents
COMpact 3000 analog/ISDN/VoIP - Firmware Version 4.0 - Version of the Manual 03 02/11 43
Installing and Switching on the PBX
Preparation
Overview of the Connections and Other Device Components
C DIP switches for terminators on the internal S
0
port
D Connector for the connection to the basic unit
Overview COMpact ISDN Module
The figure below shows the optionally available COMpact ISDN module.
A RJ-45 socket for the connection to the S
0
/U
P0
port
B Four terminal clamps (internal S
0
/U
P0
port) for the connection of ISDN end
devices
C DIP switches for terminators on the S
0
/U
P0
port
D Connector for the connection to the basic unit
E Jumper for switching over the operation mode at the S
0
/U
P0
port
Caution: Electrostatic charges can destroy sensitive components.
Divert electrostatic charges from yourself before touching the electronic
components with your hands or any tools. To do this, touch a metal object,