Configuring and Managing the PBX
Analog Connection
Switching Continuous Tone Detection at End of Call On/Off
Switching Continuous Tone Detection at End of Call On/Off
If continuous tone detection is enabled, the network provider sends a continuous tone via the
PBX; this signal is interpreted as the end of the call connection.
Switching this on/off can be done as follows:
Via the configuration manager
Requirements:
External analog port (only COMpact 3000 analog)
Network provider support for the continuous tone at the end of a call
Configuration manager, opened with sufficient authorization
Expert view (click )
Configured prefixes (country prefix and local area code)
1. Open the page CONFIGURATION > External numbers.
2. In the list field at the top, select the analog connection.
A page opens for configuring the analog connection.
3. Open the page Analogue connection > Expert configuration.
4. Select or clear the Continuous tone check box under End of the call.
Further steps:
Save your settings before you leave the page.
Switching Loop Current Detection at End of Call On/Off
If loop current detection at the end of a call is enabled, a reduction of the loop current to zero
by the PBX network provider is interpreted as the end of the call.
Switching this on/off can be done as follows:
Via the configuration manager
Enables continuous tone detection.
Disables continuous tone detection.