Service manual
STP 11-25R13-SM-TG
3 - 96
Subject Area 11: TECHNICAL SUPERVISION
CONDUCT A TECHNICAL INSPECTION (TI) FOR TURN-IN
113-575-5020
Conditions: In a tactical or garrison environment, given equipment submitted for turn-in on DA Form
2407; test equipment required (depends on noun nomenclature turned in): dual-trace oscilloscope with
10X test probes, multimeter with test leads, WFM, vectorscope, VTSG, ATSG, and TV receiver (or color
monitor, audio amplifier, and speakers). Tools and materials required: electronic equipment tool kit,
soldering tool kit (light to medium duty), DA Form 2402, DA Form 2404, DA Pam 738-750, DA Pam 750-
1, and manufacturers' manuals.
Standards: The standards are met when all deficiencies found and the condition code of the equipment
for turn-in are listed on the DA Form 2407.
Performance Measures Results
1. Review entries on the DA Form 2407. P F
2. Obtain required test equipment, forms, and service manual. P F
3. Conduct a visual inspection by looking for physical damage, missing knobs, broken
switches, broken wires or connectors, and other discrepancies.
P F
4. Set up, connect, and turn ON required test equipment. P F
5. Turn ON and operations check the equipment to determine the status of the equipment. P F
6. Annotate uncorrected faults on DA Form 2404, listing any required repair parts; date
and initial the form if no faults exist.
P F
7. Attach DA Form 2404 to the DA Form 2407. P F
8. Complete DA Form 2407 with the appropriate condition code. P F
9. Return completed forms and equipment to the production control section of the shop. P F
Evaluation Guidance: Score the soldier a GO if all steps are passed (P). Score the soldier a NO-GO if
any step is failed (F). If the soldier fails any step, show what was done wrong and how to do it correctly.
Have the soldier practice until he can correctly perform the task.
References
Required Related
DA Pam 738-750
DA Pam 750-1
Mfg Manuals