Service manual
STP 11-25R13-SM-TG
3 - 84
ESTABLISH A STUDIO-TO-TRANSMITTER LINK (STL)
113-575-1005
Conditions: In a tactical or garrison environment, given a microwave (or equivalent STL), power
amplifier, STL/TS receiver, routing switcher, speaker monitors, manufacturers' manuals, electronic
equipment tool kit, and one person on site at the transmitter.
Standards: The standards are met when the studio signal is transmitted through the STL to the
transmitter and received with no technical difficulties.
Performance Measures Results
1. Check connections and turn ON power to the STL. P F
2. Operations check the STL by verifying applicable LEDs and meter indications. P F
3. Test the STL input signal strength. P F
4. Connect the input signal to the STL. P F
5. Test the STL output signal strength. P F
6. Transmit the signal. P F
7. Receive the signal at other locations. P F
8. Adjust the signal at transmitting end for peak reception at the receiving end. P F
Evaluation Guidance: Score the soldier a GO if all steps are passed (P). Score the soldier a NO-GO if
any step is failed (F). If the soldier fails any step, show what was done wrong and how to do it correctly.
Have the soldier practice until he can correctly perform the task.
References
Required Related
Mfg Manuals TB 385-4