BETRIEBSSPANNUNG 11 ÷ 15 VDC
STROMAUFNAHME MIN 1 A
STROMAUFNAHME MAX CONT. (Nominal Leistung) 22 A
NOMINAL LEISTUNG (Tol. +10%; -5%)
2 Kanal x 4 Ohm; 0,3 THD; 12 VDC 70 W (RMS)
LIN. AUSGANGSLEISTUNG (2 Kanal x 4 Ohm; 13,8 VDC) 75 W (RMS)
LIN. AUSGANGSLEISTUNG (2 Kanal x 2 Ohm; 13,8 VDC) 135 W (RMS)
LIN. AUSGANGSLEISTUNG (2 Kanal x 1 Ohm; 13,8 VDC) 210 W (RMS)
AUSGANGSLEISTUNG MONO (4 Ohm; 13,8 VDC) Bridge 270 W(RMS)
AUSGANGSLEISTUNG MONO (2 Ohm; 13,8 VDC) Bridge 420 W(RMS)
LEISTUNG TRI MODE (4 Ohm) 75 + 75 + 270 (W RMS - pulse)
VERZERRUNGEN THD (1 KHz; 90% Nominal Leistung) 0,06 %
FREQUENZBEREICH (-3 dB; Nominal Leistung) 4 Hz - 75 KHz
DÄMPFUNGSFAKTOR (4 Ohm) 120
ANSTIEGSZEIT 4,5 µS
RAUSCHSPANNUNGSABSTAND 100 dBA
EINGANGSEMPFINDLICHKEIT 0,15 V - 1,5 V
EINGANGSIMPEDANZ 15 KOhm
AUSGANGSIMPEDANZ Stereo 1 - 2 - 4 - 8 Ohm
AUSGANGSIMPEDANZ Mono 2 - 4 - 8 Ohm
REMOTE IN 3 - 15 VDC
REMOTE OUT 12 VDC
MUTE IN 3 - 15 VDC
MUTE OUT 12 VDC
ABMESSUNGEN (BxHxT) 175 x 50 x 330 mm
LR 270 FRANÇAIS
DONNEÉS TECHNIQUES
ALIMENTATION 11 ÷ 15 VDC
TEMPS MORT 1 A
CONSOMMATION MAXI (Puissance Nominal) 22 A
PUISSANCE NOMINAL CONTINUE (Toll. +10%; -5%)
2 Ch x 4 Ohm; 0,3% DHT; 12 VDC 70 W (RMS)
PUISS. SORTIE CONTIN. (2 Ch x 4 Ohm; 13,8 VDC) 75 W (RMS)
PUISS. SORTIE CONTIN. (2 Ch x 2 Ohm; 13,8 VDC) 135 W (RMS)
PUISS. SORTIE CONTIN. (2 Ch x 1 Ohm; 13,8 VDC) 210 W (RMS)
PUISS. SORTIE MONO (4 Ohm; 13,8 VDC) Bridge 270 W (RMS)
PUISS. SORTIE MONO (2 Ohm; 13,8 VDC) Bridge 420 W (RMS)
CONNECT. TRI-MODE (4 Ohm) 75 + 75 + 270 (W RMS - pulse)
DISTORSION HARM. TOTALE (1KHz; 90% Puiss. Nom.) 0,06 %
BANDE PASSANTE (-3 dB; Puiss. Nom.) 4 Hz - 75 KHz
COEFFICIENT D'AMORTISSEMENT (4 Ohm) 120
TEMPS DE MONTÉE 4,5 µS
RATIO SIGNAL / BRUIT 100 dBA
SENSIBILITE D'ENTRÉE 0,15 V - 1,5 V
IMPEDANCE D'ENTRÉE 15 KOhm
IMPEDANCE DE SORTIE Stereo 1 - 2 - 4 - 8 Ohm
IMPEDANCE DE SORTIE Mono 2 - 4 - 8 Ohm
ENTRÉE REMOTE 3 - 15 VDC
SORTIE REMOTE 12 VDC
MUE IN 3 - 15 VDC
MUTE OUT 12 VDC
DIMENSIONS (BxHxL) 175 x 50 x 330 mm
LR 230 - LR 250 - LR 270
CONTROLS AND FUNCTIONS
INDICATOR
LIGHTS
FUNCTION
SELECTION
LEVEL CONTROL
INPUTS
ON
Lit when the
amplifier is ON.
MODE
STEREO:
The amplifier is se-
lected as stereo.
MONO IN R:
The amplifier is se-
lected as mono.
Right input is used.
PRE IN
Left - Right inputs
of the amplifier.
They can be used to
amplify the PRE out-
put of a signal source
(radio, CD-DAT), an
electronic crossover
output or an output
of any kind of signal
processor at pream-
plified level.
LEVELS
Level control for the
amplifier output.
Sensitivity varies
from 150mV to
1.5V.
SAFE
When lit it indicates
the intervention of
pro-tection circuits:
in case of overhea-
ting (temperature
exceeding 80° C /
176° F) or output
anomalies (presence
of continuous cur-
rent, short circuit, or
dangerously low load
impedance).
When protection cir-
cuits intervene the
amplifier shuts
down. Turn the am-
plifier off.
When the problem is
corrected turn the
amplifier back on.