Service manual

09/09 Rev. 5.02-02 SERVICE MANUAL Service Electronics
AP 4.4 – AP 5.4 – AP 7.t
18
Setting the Interface Parameters
With an I/O board mounted, the following additional menus appear in the prin-
ter menu:
INTERF. PARAM. > COM2 PORT
Contains all parameters required to configure the serial interface.
I/O BOARD
Contains all parameters required to configure the signal interface.
P For detailed parameter descriptions see topic section Info-printouts &
Parameters.
Menu Parameter Setting
INTERF. PARAM. >
COM2 PORT
Baud rate 9600
No. of data bits 8
Parity None
Stop Bits 1
Data synch. RTS/CTS
Serial Port Mode RS 232
SYSTEM PARAMETER External signal Singlestart
Reprint function Enabled
I/O BOARD Start delay 0.0 mm
Start print mode Pulse falling
Reprint signal Enabled
Feed Standard
Pause input Standard
Error output Print error
Error polarity Level low active
Status output Print job ready
Status polarity Level low active
End print mode Mode3 low pulse
[Tab. 5] Recommended parameter default settings.