Output Stage Brushless Motor (AP5.4)
Notes
• BLDC = brushless direct current
• Application: AP5.4 with internal rewinder
Firmware
Version
Checking the driver firmware version:
« Call
PRINT INFO > Service status.
Section „Peripheraldriver“ on the printout lists all mounted output stage
boards with the installed firmware versions.
Updating the driver firmware is done the same way as with the printer
firmware:
P See topic section Firmware.
The following files are required: BLDC_Vx.BAT resp. BLDCAP54Vx.S3B (for
firmware version x, see [Tab. 2]).
¯ CAUTION! - Don´t load the older firmware version 1 onto the new
version 2!
Layout
Printer BLDC
3.33 6
[Tab. 2] Required firmware
version for the BLDC output stage.
Peripheral sensor (CN101)
(D-Sub harness)
J103
J102
J101
Control lines, coming from
the CPU board (CN103)
Power supply (CN104)
Peripheral motor (CN102)