9. OPERATING PRECAUTIONS
(1) When mounting to a fixture, always be sure that the mount-
ing is made so that the direction of spindle movement and
the long direction of the object being measured agree and
that the spindle makes contact at the proper position.
Also, the mounting fixture should have sufficient strength and
exhibit no bending.
8. CONNECTION OF THE FINGER
LIFTER
The finger lifter can be inserted between the lift screw and the
spindle by removing the contact tip at the end of the spindle as
shown in the figure below.
Stem
Spindle
Lift Screw
Finger Lifter
Contact Tip
L L
Direction of spindle
movement should
agree with L direction.
If, as shown above, the
direction of spindle
movement and direction
L
do not agree, error will
occur in measured value
s.