Instruction manual
– 18 –
lease it to set the offset value at the instant the switch is re-
leased. The preset value setting procedure is noted below (Pre-
set Value Setting Procedure).
If “E” appears during measurement, perform a reset by switch-
ing the power off. By pressing the mode switch (for less than two
seconds) it is possible to switch through the sequence NORMAL
→ MAX → MIN → R, after which return is made to the normal
mode.
The MAX, MIN, R mode initial value is the displayed value at the
instant the MAX mode is reached by the normal mode. Once the
initial value has been set, it is held until the RESET switch is
pressed (for less than two seconds) and released. If it is neces-
sary to change the initial value, perform a reset. When doing this
the previous initial value will be cancelled and the displayed value
at the moment the MAX mode is selected from the normal mode
will be set as the new initial value. When the reset is performed,
the data output is “no data” when the RESET button is pressed
and the display is blank, and it changes to “0” when the RESET
is released and the display changes to “0”.
In the MAX, MIN, R mode if the RESET button is pressed (for
less than two seconds) and released, the initial value will be can-
celled and for the MAX or MIN mode the display will change to
the setting value. In the R mode, the display will be reset to “0”.
To return from the preset function to the normal measurement
function, press the RESET switch for longer than two seconds.
<Preset Value Setting Procedure>
If the mode switch is pressed for longer than two seconds in the
preset function, “P” and “+” or “–” will flash on the display, indicat-
ing that the preset value setting procedure has been entered.
When this procedure is followed, the measurement units will dis-
appear from the display.
Set the units in the preset function.
The maximum setting value is 6.99995 for inch units and 69.999
for mm units. It is not possible to set values above these limits.
The RESET switch is operative in returning to the preset func-
tion. Press the Mode switch for less than two seconds, and the
“+” or “–” should flash alternately. When the desired setting po-
larity appears, press the MODE switch for longer than two sec-
onds. When this is done, the polarity selected will be set. At the
same time, the flashing point will move sequentially to the right.