PROFESSIONAL SERIES Keyless Alarm Installation Guide ca 3051 ca3051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved.
BEFORE YOU BEGIN PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or routing wires near hot surfaces Avoid mounting components or routing wires near moving parts Tape or loom wires under hood for protection and appearance Use grommets when routing wires through metal surfaces Use a Digital Multi Meter for testing and verifying circuits.
INSTALLATION OF THE MAJOR COMPONENTS Control Module Select a mounting location inside the passenger compartment (behind the dash), and secure using the two screws provided. The control module can also be secured in place using cable ties. Be certain that the chosen location will not interfere with the proper operation of the vehicle.
Two Stage Shock Sensor Select a solid mounting surface for the shock sensor inside the passenger compartment (behind the dash), and mount the sensor using cable ties, making sure to allow access to the sensitivity adjustment potentiometer for use later in the installation. WIRING THE SYSTEM RED BATTERY 12V (+) Connect this wire to a +12 Volt constant source found at the vehicles ignition switch. This wire provides power for the control module.
BROWN SIREN / HORN OUTPUT This output is available to be used as a constant ( + ) siren output OR a pulsed ( - ) horn output and is selectable by changing the jumper position on the main module. Refer to the system layout on page 12 for location. SIREN: Connect the BLACK siren wire to a chassis ground using a ring terminal and self tapping screw (not supplied). Route the BROWN siren output wire from the control module through the firewall and connect to the RED wire on the siren.
GREY (-) HOOD/TRUNK TRIGGER This is an instant on ground trigger wire. It must be connected to the previously installed hood and/or trunk pin switches. GREEN NEGATIVE DOOR TRIGGER INPUT If the vehicle’s courtesy light switches have a (-) ground output when the door is opened (GM and most Imports), you must connect the Green wire to the negative output from one of the door switches.
3 Wire Ground Switched Door Locks In this application, the Orange/Green wire provides a pulsed ground lock output. Connect this wire to the wire that provides a low current ground signal from the factory door lock switch to the factory door lock control relay.
BLACK/WHITE ILLUMINATED ENTRY OUTPUT 200 mA (-) This wire provides a 30 second ground output whenever the system is disarmed using the OEM transmitter, and pulses ground when the alarm is triggered. It is used to provide the optional entry lighting feature, and will flash the vehicle's interior light when the system is triggered. This is a transistorized, low current output, and should only be used to drive an external relay.
ca3051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved.
ADDITIONAL PORTS LED PORT Route the red and blue wires in the 2 pin white connector from the LED to the control module, and plug it into the mating white connector on the side of the module. VALET / PROGRAMMING PORT Route the 2 pin red connector from the override switch previously mounted to the mating two pin connector on the module. SHOCK SENSOR PORT Route the 4 pin connector form the previously installed shock sensor to the mating 4 pin connector of the module.
PROGRAMMABLE FEATURES Changing Programmable Features: This system has several programmable features that may need to be changed based on a specific vehicle or a customer's preference. Programmable features can be changed using the bank of dip switches located on the side of the control module. To change a setting carefully flip the dip switch using a small screwdriver or pick. Use the chart below as reference. Dip Switch Feature Bank ON OFF 1 Passive Lock / 30 Sec. Output when Armed 30 Sec.
CA 3051 1-8 12 ca3051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved. (-) (+) ARM INPUT DISARM INPUT UNLOCK SENSE INPUT BATTERY 12V ( + ) SIREN HORN OUTPUT CHASSIS GROUND DOOR TRIGGER INPUT ( - ) DOOR TRIGGER INPUT ( + ) TRUNK DISARM INPUT ( + ) HOOD / TRUNK TRIGGER INPUT ( - ) IGNITION INPUT ( + ) GROUND WHEN ARMED OUTPUT SELECTABLE PULSED OUTPUT ( - ) ILLUMINATED ENTRY OUTPUT 200ma ( - ) PARKING LIGHT INPUT PARKING LIGHT OUTPUT SHOCK SENSOR PORT L.E.D.
ca3051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved.
Audiovox Electronics Corporation. Customer Service 1-800-421-3209 WWW.CODE-ALARM.COM FCC COMPLIANCE This device complies with Part 15 of the FCC rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including any interference that may cause undesired operation.