Warning lights and sirens – continued:
Zone B and D – Lower mid-body warning lights
Two (2) Code 3 LED warning lights shall be installed, one (1) on each side on the lower side of the
mid-body. The lights shall be 4” x 6”and have a red lens
Zone B and D – Upper side front warning lights
Two (2) Code 3 LED warning lights shall be installed, one (1) on each side on the upper front of the
body. The lights shall be 2” x 5” and shall have a red lens
Zone B and D – Upper side rear warning lights
Two (2) Code 3 LED warning lights shall be installed, one (1) on each side on the upper side of the
rear body. The lights shall be 2” x 5” and shall have a red lens
Zone C – Upper rear warning lights
Two (2) Code 3 LED warning lights shall be installed, one (1) each side on the upper corners of the
rear body. The lights shall be 7” x 9” and shall have a red lens on the right side and an amber lens
on the left side
Zone C – Lower rear warning lights
Two (2) Code 3 LED warning lights shall be installed, one (1) each side on the lower corners of the
rear body. The lights shall be 7” x 9” and shall have a red lens
Air System:
SCBA cylinder storage modules
Performance Advantage #CM600 cylinder mate SCBA storage unit constructed entirely from non-
corrosive materials. Automatically adjusts to contain cylinders with either 30 or 45 minute ratings
Units shall be designed for either horizontal or vertical installation
Unit shall be designed to avoid friction and damage to high pressure cylinders and include a high
strength “push to release” retention strap
9 Cylinder type and model: varies
9 Quantity of cylinders: 24
9 Location shall be in compartment #L1 and #R1
Engine driven high pressure compressor and purification system
Bauer model #H13G and H13D, 6000 psi service, or equivalent, system shall be supplied on a steel
frame designed for both the static and dynamic loads of the system
Arrangement of components on the frame shall permit unrestricted coding air flow to the
compressor and prime mover
Units shall have compressor and engine arranged in a horizontal design
System shall be designed for operation in ambient temperatures ranging between 40° F and 115° F
Installation shall not required a special foundation
All piping and tubing shall be properly supported and protected to prevent damage from vibration
All instrument tubing shall be 300 series stainless steel
System shall be warranted free from defects in material and workmanship for eighteen (18) months
from date of shipment or twelve (12) months from startup, whichever expires first. The warranty
shall not impose limitations on the system’s accumulated operating hours during the warranty
period.
Compressor
Air cooled, oil lubricated, four stage three cylinder, reciprocating compressor rated for continuous
duty at the maximum working pressure without the need for auxiliary fans or cool down cycles
Crank case shall be cast of a high strength aluminum alloy