Chapter 3 Function
3-20
3
Offset
A desired setting value can be added to/subtracted from the measurement value.
Measurement judgment will be possible from an offset in combination wit
h
“displacement judgment” by setting the size of the master workpiece
(reference measurement object) for the offset, measuring the maste
r
workpiece, and turning the “zero set” ON.
Setting range Function
Initial value
-95000 to
+95000
-Set an offset in a range from 95000
to +95000.
(The decimal point position varies
with each model.)
• Set "Offset" and turn "Zero Set" ON to make the setting value an offset value.
• The display limit of the measurement value is ±95000. Make sure that the setting
value does not exceed the display limit.
● Setting Procedure
1
Display the "Data Processing Setting"
screen while the system is in setting mode.
2
Press the [ENTER] key. The "Average
Time" screen will be displayed.
3
Press the [DOWN] key three times. The
"Offset" screen will be displayed.
4
Press the [ENTER] key. The present
offset value will be displayed. The
leftmost digit will be selected.
5
Press the [UP]/[DOWN] keys together to
change the selected digit.
6
Press the [UP]/[DOWN] key to change
the value of the selected digit or its sign.
(Example: Changing the value to
+2.500 [mm].)
7
Press the [ENTER] key and determine
the offset value.