User`s manual

Chapter 4 Communications Control
4-19
4
Output Settings
Item Command Data Description Format
+00000
Logic
+00001
Independent
+00002
2-state
Judgment Output
Selection
ROD WOD
+00003
3-state
FORMAT
1
Threshold
a
RHA WHA
-9500000 to
+9500000
-950.0000 to
+950.0000 [mm]
Threshold
b
RHB WHB
-9500000 to
+9500000
-950.0000 to
+950.0000 [mm]
Displacement
Judgment
Hysteresis
RHH WHH
+0000000 to
+9500000
+000.0000 to
+950.0000[mm]
FORMAT
2
+00000
OFF
+00001
2[ms]
+00002
4[ms]
+00003
10[ms]
+00004
20[ms]
+00005
40[ms]
+00006
100[ms]
Judgment Output
OFF-delay
ROF WOF
+00007
Hold
+00000 FULL
+00001 SET 1
Output Settings
Measurement Value
Display on Panel
RDS WDS
+00002 SET 2
FORMAT
1
*1. The data section consists of 5 digits (zero suppress is omitted) indicated in
decimal.