User`s manual
Table Of Contents
- CONTENTS
- 1 INTRODUCTION
- 2 THE CLIO SYSTEM
- 3 CLIO INSTALLATION
- 3.1 MINIMUM PC CONFIGURATION
- 3.2 FW-01 DRIVERS INSTALLATION UNDER WINDOWS XP
- 3.3 FW-01 DRIVERS INSTALLATION UNDER WINDOWS VISTA AND 7
- 3.4 SOFTWARE INSTALLATION
- 3.5 THE 'CLIO BOX'
- 3.6 RUNNING CLIO FOR THE FIRST TIME
- 3.7 SYSTEM CALIBRATION
- 3.8 CLIO SERIAL NUMBER AND DEMO MODE
- 3.9 TROUBLESHOOTING CLIO INSTALLATION
- 4 CLIO BASICS
- 5 SYSTEM OPERATIONS AND SETTINGS
- 6 COMMON MEASUREMENT INTERFACE
- 7 SIGNAL GENERATOR
- 8 MULTI-METER
- 9 FFT, RTA AND “LIVE” TRANSFER FUNCTION
- 10 MLS & LOG CHIRP
- 11 SINUSOIDAL
- 12 WATERFALL , DIRECTIVITY & 3D
- 12.1 INTRODUCTION
- 12.2 WATERFALL, DIRECTIVITY & 3D CONTROL PANEL
- 12.3 WATERFALL SPECIFIC CONTROLS
- 12.4 MAKING A CUMULATIVE SPECTRAL DECAY
- 12.5 DIRECTIVITY SPECIFIC CONTROLS
- 12.6 MEASURING LOUDSPEAKER SINGLE POLAR DATA (1D MODE)
- 12.7 REPRESENTING SINGLE POLAR DATA
- 12.8 3D SPECIFIC CONTROLS
- 12.9 MEASURING LOUDSPEAKER SINGLE POLAR DATA (3D MODE)
- 12.10 MEASURING FULL SPHERE LOUDSPEAKER POLAR DATA (3D MODE)
- 12.11 REPRESENTING 3D BALLOON DATA
- 12.12 EXPORT 3D BALLOON DATA
- 13 MEASURING IMPEDANCE AND T&S PARAMETERS
- 14 LINEARITY & DISTORTION
- 15 ACOUSTICAL PARAMETERS
- 16 Leq LEVEL ANALYSIS
- 17 WOW AND FLUTTER
- 18 WAVELET ANALYSIS
- BIBLIOGRAPHY
- NORMS

5.7 STARTUP OPTIONS AND GLOBAL SETTINGS
You can start CLIO directly clicking on the CLIO.exe executable that is saved in the
installation directory (usually C:\Program Files\Audiomatica\CLIO 10); you may
also access CLIO either from Start Menu>Programs>CLIO 10 or creating a
shortcut on your Desktop.
A second way to run CLIO is to click on a registered file; in this way you will not
only run the program but also load the file into the appropriate measurement
menu.
CLIO creates a temporary folder for several uses. This folder is located under the
Common Application Data folder with the following path (Windows XP):
C:\Documents and Settings\All Users\Application Data\Audiomatica\CLIO 10\Temp
under Windows Vista or 7: C:\ProgramData\Audiomatica\CLIO 10\Temp
CLIO relies, during startup, on a configuration file named cliofw.stp which resides
in the temporary folder.
This file is written each time the program ends and saves several settings that will
be reloaded and reconfigure your system.
Among them we find (see chapters 4 and 5):
- program Options
- generator output level
- input sensitivity
- phantom power supply state
- autorange state
- microphone settings
- CLIOQC Amplifier & SwitchBox
- color scheme and other setup settings
- main window state
- global reference level
- autoscale state
Note: It is possible to return the system to its initial default state (after
installation) by deleting the cliofw.stp file.
5.7.1 SAVING MEASUREMENT SETTINGS
Measurements settings can be saved from within the various measurement menu;
to do this simply check the Save Settings box in the Settings dialog of each menu
(Fig.5.10); refer to specific menu chapters for details on settings.
Fig.5.10 Save Settings check box
Settings are saved in the mls.stp (MLS&LogChirp), sin.stp (Sinusoidal), fft.stp
(FFT), wtf.stp (Waterfall&Directivity), acp.stp (Acoustical Parameters) , lin.stp
(Linearity&Distortion) , leq.stp (Leq) files inside the temporary folder.
Upon finding one of these files CLIO will reset the corresponding menu to the saved
settings.
5 SYSTEM OPERATIONS AND SETTINGS 69