User`s manual

Table Of Contents
5.3.2 EXPORTING DATA
CLIO is able to export the currently active measurement in an ASCII file (*.txt).
Fig.5.4 Export dialog
Upon performing this choice you will be prompted by the Export dialog. Depending
on the measurement menu you are working with, it will be possible to choose
different data to export. Here is a list of the possibilities, menu by menu:
MLS > Display Frequency Data
The program will export the frequency data as they are displayed on the screen,
with resolution variable from 256 to 2048 points, regardless the current MLS
size.
MLS > FFT Frequency Data
The program will export the frequency data with the resolution of the current
MLS size.
MLS > Time Data
The program will export the acquired impulse response or active post process.
FFT > Display Frequency Data
The program will export the processed frequency data as they are displayed on
the screen, with its internal resolution of 2048 points, regardless the current FFT
size.
FFT > FFT Frequency Data
The program will export the processed frequency data with the resolution of the
current FFT size.
FFT > Last FFT Data
The program will export the last calculated FFT frequency data with the
resolution of the current FFT size.
FFT > Last Time Data
The program will export the last captured time data with the resolution of the
current FFT size.
Sinusoidal > Frequency Data
The program will export the acquired frequency data with their fraction of octave
frequency resolution.
Sinusoidal > Frequency + Distortion Data
As above plus THD and R&B data.
T&S > T&S Parameter
Linearity&Distortion > Distortion data
Wow&Flutter > Wow&Flutter data
5 SYSTEM OPERATIONS AND SETTINGS 61