18.2 WAVELET ANALYSIS CONTROL PANEL
Fig 18.1 show the Wavelet Analysis control panel, the behavior of this menu is
similar to the Waterfall menu as seen in chapter 18.
As already stated the source of data for Wavelet Analysis is an impulse response,
please refer to chapter 10 (MLS&LogChirp) to have details on how to measure an
impulse response.
18.2.1 COMMON TOOLBAR BUTTONS AND DROP DOWN LISTS
Starts a Wavelet Analysis calculation.
If pressed each frequency slice of the spectrogram will be referenced to the its
energy time maximum; the plot can be interpreted as the energy decay of the
system.
Enters the settings dialog. See 18.3.
Moves the plot up.
Moves the plot down.
Expands the plot changing its Z scale. The Z range is reduced.
Compresses the plot changing its Z scale. The Z range is increased.
When pressed the wavelet analysis (scalogram) plot is displayed.
When pressed the grid is displayed.
When pressed the impulse response loaded in memory is displayed.
Loads an impulse response from disk (from MLS binary files).
Takes current MLS impulse response for wavelet calculation.
220 18 WAVELET ANALYSIS