User`s manual
Table Of Contents
- CONTENTS
- 1 INTRODUCTION
- 2 THE CLIO SYSTEM
- 3 CLIO INSTALLATION
- 3.1 MINIMUM PC CONFIGURATION
- 3.2 FW-01 DRIVERS INSTALLATION UNDER WINDOWS XP
- 3.3 FW-01 DRIVERS INSTALLATION UNDER WINDOWS VISTA AND 7
- 3.4 SOFTWARE INSTALLATION
- 3.5 THE 'CLIO BOX'
- 3.6 RUNNING CLIO FOR THE FIRST TIME
- 3.7 SYSTEM CALIBRATION
- 3.8 CLIO SERIAL NUMBER AND DEMO MODE
- 3.9 TROUBLESHOOTING CLIO INSTALLATION
- 4 CLIO BASICS
- 5 SYSTEM OPERATIONS AND SETTINGS
- 6 COMMON MEASUREMENT INTERFACE
- 7 SIGNAL GENERATOR
- 8 MULTI-METER
- 9 FFT, RTA AND “LIVE” TRANSFER FUNCTION
- 10 MLS & LOG CHIRP
- 11 SINUSOIDAL
- 12 WATERFALL , DIRECTIVITY & 3D
- 12.1 INTRODUCTION
- 12.2 WATERFALL, DIRECTIVITY & 3D CONTROL PANEL
- 12.3 WATERFALL SPECIFIC CONTROLS
- 12.4 MAKING A CUMULATIVE SPECTRAL DECAY
- 12.5 DIRECTIVITY SPECIFIC CONTROLS
- 12.6 MEASURING LOUDSPEAKER SINGLE POLAR DATA (1D MODE)
- 12.7 REPRESENTING SINGLE POLAR DATA
- 12.8 3D SPECIFIC CONTROLS
- 12.9 MEASURING LOUDSPEAKER SINGLE POLAR DATA (3D MODE)
- 12.10 MEASURING FULL SPHERE LOUDSPEAKER POLAR DATA (3D MODE)
- 12.11 REPRESENTING 3D BALLOON DATA
- 12.12 EXPORT 3D BALLOON DATA
- 13 MEASURING IMPEDANCE AND T&S PARAMETERS
- 14 LINEARITY & DISTORTION
- 15 ACOUSTICAL PARAMETERS
- 16 Leq LEVEL ANALYSIS
- 17 WOW AND FLUTTER
- 18 WAVELET ANALYSIS
- BIBLIOGRAPHY
- NORMS

12.12.1 EXPORT EASE .XHN AND CLF V2 .TAB FILES
In case of EASE .xhn and CLF v2 .tab format is selected in the File And Export
Format Group then the General Information, On Axis Response and Impedance &
Power groups are active.
Output File defines the file name and location where the file will be saved; it is
possible to choose it clicking on the browse for Choose Output File button (...).
The Loudspeaker Name and Manufacturer Name fields will be used into the
exported text file.
The Frequency Range can go from 100 Hz to 10 kHz in case of EASE .xhn, from
25 Hz to 20 kHz in case of CLF v2 .tab. The frequency range to export can be
modified using the combo boxes.
The On-Axis Response group let the user decide to use the data set on-axis
measurement or use an MLS file as on-axis reference. It is also possible to apply a
Level Shift to our measured response to correct for power and distance different
from the required 1W/1m. A basic calculation that calculates the required level shift
as function of the Drive Level in W applied and Measurement Distance between
loudspeaker and microphone.
Similarly to the previous group, the Impedance & Power group let the user decide
to use a real measured impedance in .sini format or a nominal value. Into the same
group the user can specify a power level (valid for all bands) for the source.
It is clear that the functions of this export menu are minimal, but they successfully
meet the user need to create loudspeaker models used by the most common
simulation software.
Once the output text file is saved, it may be necessary to preprocess with a text
editor to add or modify information.
Figure 12.33 report an example of a data set exported to CLF v2. tab format and
imported by the CLF software.
figure 12.33
12 WATERFALL , DIRECTIVITY & 3D 179