User`s manual
Table Of Contents
- CONTENTS
- 1 INTRODUCTION
- 2 THE CLIO SYSTEM
- 3 CLIO INSTALLATION
- 3.1 MINIMUM PC CONFIGURATION
- 3.2 FW-01 DRIVERS INSTALLATION UNDER WINDOWS XP
- 3.3 FW-01 DRIVERS INSTALLATION UNDER WINDOWS VISTA AND 7
- 3.4 SOFTWARE INSTALLATION
- 3.5 THE 'CLIO BOX'
- 3.6 RUNNING CLIO FOR THE FIRST TIME
- 3.7 SYSTEM CALIBRATION
- 3.8 CLIO SERIAL NUMBER AND DEMO MODE
- 3.9 TROUBLESHOOTING CLIO INSTALLATION
- 4 CLIO BASICS
- 5 SYSTEM OPERATIONS AND SETTINGS
- 6 COMMON MEASUREMENT INTERFACE
- 7 SIGNAL GENERATOR
- 8 MULTI-METER
- 9 FFT, RTA AND “LIVE” TRANSFER FUNCTION
- 10 MLS & LOG CHIRP
- 11 SINUSOIDAL
- 12 WATERFALL , DIRECTIVITY & 3D
- 12.1 INTRODUCTION
- 12.2 WATERFALL, DIRECTIVITY & 3D CONTROL PANEL
- 12.3 WATERFALL SPECIFIC CONTROLS
- 12.4 MAKING A CUMULATIVE SPECTRAL DECAY
- 12.5 DIRECTIVITY SPECIFIC CONTROLS
- 12.6 MEASURING LOUDSPEAKER SINGLE POLAR DATA (1D MODE)
- 12.7 REPRESENTING SINGLE POLAR DATA
- 12.8 3D SPECIFIC CONTROLS
- 12.9 MEASURING LOUDSPEAKER SINGLE POLAR DATA (3D MODE)
- 12.10 MEASURING FULL SPHERE LOUDSPEAKER POLAR DATA (3D MODE)
- 12.11 REPRESENTING 3D BALLOON DATA
- 12.12 EXPORT 3D BALLOON DATA
- 13 MEASURING IMPEDANCE AND T&S PARAMETERS
- 14 LINEARITY & DISTORTION
- 15 ACOUSTICAL PARAMETERS
- 16 Leq LEVEL ANALYSIS
- 17 WOW AND FLUTTER
- 18 WAVELET ANALYSIS
- BIBLIOGRAPHY
- NORMS

11.2.4 SINUSOIDAL POST PROCESSING TOOLS
The POST PROCESSING Dialog gives access to very powerful tools that, once
defined, can be saved, reloaded and automatically be applied to every executed
measurement.
Loads a Sinusoidal process.
Saves a Sinusoidal process.
Adds a data value or compatible file to the current measurement.
Subtracts a data value or compatible file to the current measurement.
Multiplies the current measurement by a data value or compatible file.
Divides the current measurement by a data value or compatible file.
Shifts the current measurement by a dB value.
Multiplies the current measurement by complex frequency.
Divides the current measurement by complex frequency.
Uses a reference measurement file taken at speaker terminals to calculate 1m
sensitivity in dBSPL/W. The reference file should have dBV Y units while the one
in memory should be in dBSPL.
Temporally shifts the current measurement by a ms value. Affects phase
response.
Merges the current measurement with the part below the selected transition
frequency of a selected compatible file.
Combines the current measurement and the selected file to obtain a constant
current impedance measurement. Both files should be in dBV.
Combines the current measurement and the selected file to obtain a constant
voltage impedance measurement. Both files should be in dBV.
11 SINUSOIDAL 141