User`s manual

Table Of Contents
11 SINUSOIDAL
11.1 INTRODUCTION
Within Sinusoidal, it is possible to carry out Frequency Response Analysis,
Impedance Analysis and Distortion Analysis. As should be obvious the stimuli used
is a Sinusoidal signal, stepped or continuously swept within user defined Frequency
limits. Although Sinusoidal steady state analysis is among the oldest and more
traditional kind of measure, CLIO merges the reliability of this well known technique
with the power of advanced DSP. The completely programmable Gating feature
allows the user to add quasi-anechoic frequency response capability. Simultaneous,
two channels, stereo measurements can be performed.
11.2 SINUSOIDAL CONTROL PANEL
11.2.1 TOOLBAR BUTTONS
Starts the sinusoidal measurement.
If pressed the measurements will be autosaved. The current autosave definitions
apply; see 6.3.1 for details.
If pressed the measurements will be autostored in overlays.
Automatically applies the defined post-process after the measurement has been
taken.
Enters the Sinusoidal Post-Process Dialog, described below.
When a stereo measurement is done divides channel A by channel B and shows
result.
Displays the phase response instead of modulus response.
Enters the Sinusoidal Setting Dialog, described in detail below. It is the heart of
the whole menu and should be thoroughly understood before pressing Go.
Harmonic Distortion Selection Drop-Down
If the distortion products have been calculated, interactively select the one to
display.
11 SINUSOIDAL 137