User`s manual

Table Of Contents
10.2.1 TOOLBAR BUTTONS
Starts an MLS & LOG CHIRP measurement.
If pressed the measurements will be autosaved. The current autosave definitions
apply; see 6.3.1 for details.
If pressed the measurements will be autostored in overlays.
Selects the Loop mode. When in Loop mode the MLS & LOG CHIRP measurement
is automatically repeated until the user presses a keystroke or releases the
button. If Autosave is active the loop mode ends after the total files to be
autosaved are done.
When an MLS & LOG CHIRP measurement is taken, it automatically applies the
selected post-process.
Enters the MLS & LOG CHIRP Process dialog box.
Enters the MLS & LOG CHIRP settings dialog box.
Enters Time domain.
Enters Frequency domain.
Displays phase.
Set wrapped or unwrapped phase
Displays group delay.
By right clicking either on phase or group delay button the kind of calculation
can be selected:
Normal displays the measured phase (group delay) curve referring to the selected
time domain data.
Minimum calculates and displays the phase (group delay) curve, related to the
current modulus curve, in the assumption of minimum phase behaviour (i.e. the
Hilbert transform of the log magnitude).
Excess calculates and displays the phase (group delay) curve as the difference
between the Normal and the Minimum ones.
10.2.2 TOOLBAR DROP DOWN LISTS
input channel
Selects the input channel configuration.