Specifications
While the whole procedure can be carried with Impedance present in memory but
not saved, we strongly suggest that you carry out the two measurements and save
them with meaningful names. It is a good idea to include the amount of Mass (or
Volume) used in the name of the second file while “FreeAir” is a good choice for the
first.
With the Free Air measurement in memory open the CLIO Pocket Option Dialog
and choose T&S Parameters Tab. Check that Free Air Radio Button is selected and
fill the required data.
Note that if the Loudspeaker is connected the DC resistance Re can be directly
measured by CLIO clicking on the Measure button. Also notice that Diameter and
Area are either/or options. You may set one and the other will be set accordingly
once the field is exited. Confirm and Close pressing OK. Now Clicking on the T&S
Parameters Button the Free Air parameters should appear.
38 4 ENJOY CLIO POCKET CLIO POCKET - SURVIVAL GUIDE