2. Configure the Call Forward parameters for each port according to the table below.
3. Click the Submit button to save your changes.
4. To save the changes so they are available after a power fail refer to Section
5.12 on page
140.
Table
5-24: Call Forward Table
Parameter Description
Forward Type
Not in use [0] = Don’t forward incoming calls (default).
On Busy [1] = Forward incoming calls when the gateway port is busy.
Immediate [2] = Forward any incoming call to the Phone number specified.
No reply [3] = Forward incoming calls not answered with the time
specified in the ‘Time for No Reply Forward’ field.
On busy or No reply [4] = Forward incoming calls when the port is busy or when calls
are not answered after a configurable period of time.
Do Not Disturb [5] = Immediately reject incoming calls.
Forward to Phone Number
Enter the telephone number to which the call is forwarded.
Note: When a Gatekeeper isn’t used, the ‘forward to’ phone number must be
specified in the ‘Tel to IP Routing’ table of the forwarding gateway.
Time for No Reply Forward
If you have set the Forward Type for this port to no reply, enter the number of
seconds the VoIP gateway waits before forwarding the call to the phone number
specified.
Parameter Name in ini File Parameter Format
FwdInfo_x
FwdInfo_<Gateway Port Number> = <Forward Type>, <Forward to Phone Number>,
<Time for No Reply Forward>
For example:
FwdInfo_0 = 1,1001
FwdInfo_1 = 1,2003
FwdInfo_2 = 3,2005,30
Note 1: The numbering of gateway ports starts with 0.
Note 2: This parameter can appear up to 24 times for MP-124.