User`s manual

MP-1xx H.323 User’s Manual 4. Getting Started
Version 4.4 35 March 2005
4 Getting Started
The MP-1xx is supplied with application software already resident in its flash memory (with
factory default parameters).
Section
4.1 below describes how to assign an IP address to the MP-1xx, while Section 4.2 on
page 36 describes how to set up the MP-1xx with basic parameters using a standard Web
browser (such as Microsoft
TM
Internet Explorer).
For detailed information on how to fully configure the gateway refer to the Web Interface,
described in Section
5 on page 39.
4.1 Assigning the MP-1xx IP Address
To assign an IP address to the MP-1xx use one of the following methods:
HTTP using a Web browser (refer to Section
4.1.1 below).
BootP (refer to Section
4.1.2 on page 36).
Dynamic Host Control Protocol (DHCP) (refer to Section
10.2 on page 173).
Serial communication software (e.g., HyperTerminal
TM
) connected to the MP-1xx via the RS-
232 port (refer to Section 9.2.2 on page 168).
The default networking parameters are show in Table
4-1.
You can use the ‘Reset’ button to restore the MP-1xx networking parameters to their factory
default values (refer to Section
4.2 on page 36).
Table
4-1: MP-1xx Default Networking Parameters
FXS or FXO Default Value
FXS
10.1.10.10
FXO
10.1.10.11
MP-1xx default subnet mask is 255.255.0.0, default gateway IP address is 0.0.0.0
4.1.1 Assigning an IP Address Using HTTP
To assign an IP address using HTTP, take these 8 steps:
1. Connect your computer to the MP-1xx. Either connect the network interface on your
computer to a port on a network hub / switch (refer to Table
3-1 on page 29 - RJ-45 Ethernet
cable), or use an Ethernet cross-over cable to directly connect the network interface on your
computer to the RJ-45 jack on the MP-1xx.
2. Change your PC’s IP address and subnet mask to correspond with the MP-1xx factory
default IP address and subnet mask, shown in Table
4-1. For details on changing the IP
address and subnet mask of your PC, refer to Windows™ Online Help (Start>Help).
3. Access the MP-1xx Embedded Web Server (refer to Section
5.6 on page 41).
4. In the ‘Quick Setup’ screen (shown in Figure
4-1), set the MP-1xx ‘IP Address’, ‘Subnet
Mask’ and ‘Default Gateway IP Address’ fields under ‘IP Configuration’ to correspond with
your network IP settings. If your network doesn’t feature a default gateway, enter a dummy
value in the ‘Default Gateway IP Address’ field.
5. Click the Reset button and click OK in the prompt; the MP-1xx applies the changes and
restarts. This takes approximately 1 minute to complete. When the MP-1xx has finished
restarting, the Ready and LAN LEDs on the front panel are lit green.