User`s manual
MP-1xx H.323
MP-1xx H.323 User’s Manual 228 Document #: LTRT-65104
Table G-3: acBoardCallResourcesAlarm Alarm Trap
Alarm:
acBoardCallResourcesAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.8
Default Severity
Major
Event Type:
processingErrorAlarm
Probable Cause:
softwareError (46)
Alarm Text:
Call resources alarm
Status Changes:
Condition: Number of free channels exceeds the predefined RAI high threshold.
Alarm Status: Major
Note: To enable this alarm the RAI mechanism must be activated (EnableRAI = 1).
Condition: Number of free channels falls below the predefined RAI low threshold.
Alarm Status: Cleared
Table G-4: acBoardControllerFailureAlarm Alarm Trap
Alarm:
acBoardControllerFailureAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.9
Default Severity
Minor
Event Type:
processingErrorAlarm
Probable Cause:
softwareError (46)
Alarm Text:
Controller failure alarm
Status Changes:
Condition: Gatekeeper has not been found
Alarm Status: Major
Additional Info: The IP address of the lost Gatekeeper.
Describes the configuration of the gateway: ‘FallBack to internal routing used’ and / or
‘RedundantGK enabled’
Condition: Gatekeeper is found.
The clear message includes the IP address of this Gatekeeper.
Alarm Status: Cleared
Table G-5: acBoardOverloadAlarm Alarm Trap
Alarm:
acBoardOverloadAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.11
Default Severity
Major
Event Type:
processingErrorAlarm
Probable Cause:
softwareError (46)
Alarm Text:
Board overload alarm
Status Changes:
Condition: An overload condition exists in one or more of the system components.
Alarm Status: Major
Condition: The overload condition passed
Alarm Status: Cleared