8.10.4.4 MP-108/FXO Configuration (Using the Embedded Web Server)
To configure the MP-108/FXO, take these 4 steps:
1. In the ‘Endpoint Phone Numbers’ screen, assign the phone numbers 200 to 207 for the
gateway’s endpoints.
2. In the ‘Automatic Dialing’ screen, enter the phone numbers of the MP-108/FXS gateway in
the ‘Destination Phone Number’ fields. When a ringing signal is detected at port #1, the FXO
gateway automatically dials the number ‘100’.
3. In the ‘Tel To IP Routing’ screen, enter 10 in the ‘Destination Phone Prefix’ field, and the IP
address of the MP-108/FXS gateway (10.1.10.3) in the field ‘IP Address’.
4. In the ‘Protocol Management’ screen, set the parameter ‘
Dialing Mode’ to ‘Two Stage’
(
IsTwoStageDial=1).