User`s manual
SIP User's Manual 5. Web Management
Version 5.0 87 December 2006
¾ To configure the Metering Tones, take these 6 steps:
1. Open the ‘Metering Tones’ screen (Protocol Management menu > Advanced
Parameters submenu > Metering Tones option); the ‘Metering Tones’ screen is
displayed.
Figure 5-11: Metering Tones Parameters Screen
2. From the ‘Generate Metering Tones’ drop-down list, select the method used to
configure the metering tones that are generated to the Tel side (refer to Table 5-10). If
you selected ‘Internal Table’, you must configure the ‘Charge Codes Table’. To
configure the ‘Charge Codes Table’, refer to Section 5.5.2.3.1 below. Continue with
Step 4.
3. From the ‘Metering Tone Type’ drop-down list, select the type of the metering tone
according to your requirements (refer to Table 5-10).
4. In the Tel to IP Routing table (Section 5.5.5.2 on page 100) assign a charge code rule
to the routing rules you require. When a new call is established, the Tel to IP Routing
table is searched for the destination IP addresses. Once a route is found, the Charge
Code (configured for that route) is used to associate the route with an entry in the
Charge Codes table.
5. Click the Submit button to save your changes.
6. To save the changes so they are available after a power fail, refer to Section 5.10.2 on
page 205.
Table 5-10: Metering Tones Parameters
Parameter Description
Generate Metering Tones
[PayPhoneMeteringMode]
Determines the method used to configure the metering tones that are generated to
the Tel side (FXS gateways only).
Disable
[0] = Metering tones aren’t generated (default).
Internal Table
[1] = Metering tones are generated according to the internal table
configured by the parameter ChargeCode.
RADIUS
[2] = N/A.
Note: This parameter is not applicable to the Metering Tones Relay mechanism
(described in Section
11 on page 277).
Metering Tones Type
[MeteringType]
Defines the metering tone (12 kHz or 16 kHz) that is detected by FXO gateways
and generated by FXS gateways.
12 kHz
[0] = 12 kHz metering tone (default).
16 kHz
[1] = 16 kHz metering tone.
Note: Suitable (12 kHz or 16 KHz) coeff must be used for both FXS and FXO
gateways.
Charge Codes Table For detailed information on configuring the Charge Codes Table, refer to Section
5.5.2.3.1 below.