User`s manual

MediaPack
SIP User's Manual 44 Document #: LTRT-65408
Table 4-2: Configuration Parameters Available via the Voice Menu
(continues on pages 43 to 44)
Item Number at
Menu Prompt
Description
12
MGCP call agent port number (N/A)
99
Voice menu password (initially 12345).
Note: The voice menu password can also be changed using the parameter
‘VoiceMenuPassword’ (refer to Table
5-50 on page 174).
4.2.4 Assigning an IP Address Using the CLI
First access the CLI using a standard Telnet application or using a serial communication
software (e.g., HyperTerminal
TM
) connected to the MediaPack RS-232 port (refer to
Section 4.2.4.1 below). Then assign the MediaPack an IP address (refer to Section 4.2.4.2
below).
4.2.4.1 Access the CLI
¾ To access the CLI via the Embedded Telnet Server, take these 3
steps:
1. Enable the Embedded Telnet Server:
a. Access the MediaPack Embedded Web Server (refer to Section 5.3 on page 51).
b. Set the parameter ‘Embedded Telnet Server’ (under Advanced Configuration >
Network Settings > Application Settings) to ‘Enable (Unsecured)’ or ‘Enable
Secured (SSL)’.
c. Click the Maintenance button on the main menu bar; the 'Maintenance Actions'
screen is displayed.
d. From the 'Burn to FLASH' drop-down list, select 'Yes'.
e. Click the Reset button; the MediaPack is shut down and re-activated. A message
about the waiting period is displayed. The screen is refreshed.
2. Use a standard Telnet application to connect to the MediaPack Embedded Telnet
Server. Note that if the Telnet server is set to SSL mode, a special Telnet client is
required on your PC to connect to the Telnet interface over a secured connection.
3. Login using the username (‘Admin’) and password (‘Admin’).
¾ To access the CLI via the RS-232 port, take these 2 steps:
1. Connect the RS-232 port to your PC (For the MP-124, refer to Section 3.2.4.1 on page
40. For the MP-11x, refer to Section 3.1.5.1 on page 34).
2. Use serial communication software (e.g., HyperTerminal
TM
) to connect to the
MediaPack.
Set your serial communication software to the following communications port settings:
Baud Rate: 115,200 bps (MP-124), 9,600 bps (MP-11x)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
The CLI prompt becomes available.