Table F-2: acBoardTemperatureAlarm Alarm Trap
Alarm:
acBoardTemperatureAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.3
Default Severity
Critical
Event Type:
equipmentAlarm
Probable Cause:
temperatureUnacceptable (50)
Alarm Text:
Board temperature too high
Status Changes:
Condition:
Temperature is above 60 degrees C (140 degrees F)
Alarm status: Critical
Condition:
After raise, temperature falls below 55 degrees C (131 degrees F)
Alarm status: Cleared
Corrective Action:
Inspect the system. Determine if all fans in the system are properly operating.
Table F-3: acgwAdminStateChange Alarm Trap
Alarm:
acgwAdminStateChange
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.7
Default Severity
Major
Event Type:
processingErrorAlarm
Probable Cause:
outOfService (71)
Alarm Text:
Network element admin state change alarm Gateway is <text>
Status Changes:
Condition:
Admin state changed to shutting down
Alarm status: Major
<text value>: Shutting down. No time limit.
Condition:
Admin state changed to locked
Alarm status: Major
<text value>: Locked
Condition:
Admin state changed to unlocked
Alarm status: Cleared
Corrective Action:
A network administrator has taken an action to lock the device. No corrective
action is required.