User`s manual

SIP User's Manual 3. Installing the MediaPack
Version 5.0 33 December 2006
3.1.5 Cabling the MP-11x
Cable your MP-11x according to each section of Table 3-3. For detailed information on the
MP-11x rear panel connectors, refer to Table 2-2 on page 26.
Table 3-3: MP-11x Cables and Cabling Procedure
Cable Cabling Procedure
RJ-45 Ethernet
cable
Connect the Ethernet connection on the MP-11x directly to the network using a crossover
RJ-45 Ethernet cable. For connector pinouts refer to Figure
3-4 below.
Note that when assigning an IP address to the MP-11x using HTTP (under Step
1 in
Section 4.2.1), you may be required to disconnect this cable and re-cable it differently.
Connect the RJ-11 FXS connectors to fax
machines, modems, or phones.
RJ-11 two-wire
telephone cords
Connect the RJ-11 FXO connectors to telephone
exchange analog lines or PBX extensions.
Ensure that FXS and FXO ports are
connected to the correct devices,
otherwise damage can occur.
The RJ-11 connector pinouts is
described in Figure
3-5).
Lifeline
For detailed information on setting up the Lifeline, refer to the procedure in Section
3.1.5.2 on page 34.
RS-232 serial cable
For detailed information on connecting the MP-11x RS-232 port to your PC, refer to
Section 3.1.5.1.
AC Power cable
Connect the MP-11x power socket to the mains.
Warning: To reduce the risk of fire, use only No. 26 AWG or larger
telecommunication line cords.
Warning: Units must be connected by service personnel to a socket-outlet with a
protective earthing connection.
Figure 3-4: RJ-45 Ethernet Connector Pinouts
1 2 3 4 5 6 7 8
RJ-45 Connector and Pinout
4, 5, 7, 8
not
connected
1 - Tx+
2 - Tx-
3 - Rx+
6 - Rx-
Figure 3-5: RJ-11 Phone Connector Pinouts
1 2 3 4
1 -
2 -
3 -
4 -
Not connected
RJ-11 Connector and Pinout
Not connected
Tip
Ring