User`s manual

MediaPack
SIP User's Manual 262 Document #: LTRT-65408
10.2 Establishing a Serial Communications Link with the
MediaPack
Use serial communication software (e.g., HyperTerminal
TM
) to establish a serial
communications link with the MediaPack via the RS-232 connection. You can use this link
to change the networking parameters (Section 4.2.4 on page 44) and to receive error /
notification messages.
¾
To establish a serial communications link with the MediaPack via
the RS-232 port, take these 2 steps:
1. Connect the RS-232 port to your PC (For the MP-124, refer to Section 3.2.4.1 on page
40. For the MP-11x, refer to Section 3.1.5.1 on page 34).
2. Use a serial communication software (e.g., HyperTerminal
TM
) with the following
communications port settings:
Baud Rate: 115,200 bps (MP-124), 9,600 bps (MP-11x)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note that after resetting the gateway, the information, shown in Figure 11-1 below, appears
on the terminal screen. This information can be used to determine possible MediaPack
initialization problems, such as incorrectly defined (or undefined) local IP address, subnet
mask, etc.
Figure 10-1: RS-232 Status and Error Messages
MAC address = 00-90-8F-01-00-9E
Local IP address = 10.1.37.6
Subnet mask = 255.255.0.0
Default gateway IP address = 10.1.1.5
TFTP server IP address = 10.1.1.167
Boot file name = ram35136.cmp
INI file name = mp108.ini
Call agent IP address = 10.1.1.18
Log server IP address = 0.0.0.0
Full/Half Duplex state = HALF DUPLEX
Flash Software Burning state = OFF
Serial Debug Mode = OFF
Lan Debug Mode = OFF
BootLoad Version 1.75
Starting TFTP download... Done.
MP108 Version 3.80.00