User`s manual

MediaPack
SIP User's Manual 182 Document #: LTRT-65408
5.6.6.4 Advanced Configuration ini File Parameters
Table 5-55 describes the board parameters that can only be configured via the ini file.
Table 5-55: Board, ini File Parameters (continues on pages 182 to 184)
ini File Parameter Name Valid Range and Description
LifeLineType
The Lifeline is activated on:
0 = Power down (default)
1 = Power down or when link is down (physical disconnect)
2 = Power down or when link is down or on network failure (logical link
disconnect)
Note: To enable Lifeline switching on network failure, LAN watch dog
must be activated (EnableLANWatchDog=1).
EnableDiagnostics
Checks the correct functionality of the different hardware components
on the gateway. On completion of the check, if the test fails, the
gateway sends information on the test results of each hardware
component to the Syslog server.
0 = Rapid self-test mode (default).
1 = Detailed self-test mode (full test of DSPs, PCM, Switch, LAN, PHY
and Flash).
2 = A quicker version of the Detailed self-test mode (full test of DSPs,
PCM, Switch, LAN, PHY, but partial test of Flash).
For detailed information, refer to Section
13.1 on page 301.
EnableParametersMonitoring
Obsolete parameter, use the parameter ‘ActivityListToLog’ instead.
WatchDogStatus
0 = Disable gateway’s watch dog.
1 = Enable gateway’s watch dog (default).
DisableRS232
0 = RS-232 serial port is enabled (default).
1 = RS-232 serial port is disabled.
The RS-232 serial port can be used to change the networking
parameters (Section
4.2.4 on page 44) and to view error / notification
messages.
For information on establishing a serial communications link with the
MediaPack, refer to Section
10.2 on page 262).
DisableWebTask
0 = Enable Web management (default)
1 = Disable Web management
ResetWebPassword
Resets the username and password of the primary and secondary
accounts to their defaults.
0 = Password and username retain their values (default).
1 = Password and username are reset (for the default username and
password, refer to Table
4-1 on page 41).
Note: The username and password cannot be reset from the Web (i.e.,
via AdminPage or by loading an ini file).
DisableWebConfig
0 = Enable changing parameters from Web (default)
1 = Operate Web server in ‘read only’ mode
HTTPport
HTTP port used for Web management (default = 80)
HeartBeatDestIP
Destination IP address (in dotted format notation) to which the gateway
sends proprietary UDP ‘ping’ packets.
The default IP address is 0.0.0.0.
HeartBeatDestPort
Destination UDP port to which the heartbeat packets are sent.
The range is 0 to 64000.
The default is 0.
HeartBeatIntervalmsec
Delay (in msec) between consecutive heartbeat packets.
10 = 100000.
-1 = disabled (default).