User`s manual

MediaPack
SIP User's Manual 180 Document #: LTRT-65408
5.6.6.2 Configuring the SNMP Community Strings
Use the SNMP Community Strings table to configure up to five read-only and up to five
read / write SNMP community strings, and to configure the community string that is used
for sending traps. For detailed information on SNMP community strings, refer to Section
14.8.1 on page 313.
¾
To configure the SNMP Community Strings, take these 5 steps:
1. Access the ‘Management Settings’ screen (Advanced Configuration menu >
Management Settings); the ‘Management Settings’ screen is displayed (Figure 5-51).
2. Open the SNMP Community Strings screen by clicking the arrow sign (-->) to the right
of the SNMP Community Strings label; the SNMP Community Strings screen is
displayed (Figure 5-53).
3. Configure the SNMP Community Strings parameters according to Table 5-53 below.
4. Click the Submit button to save your changes.
5. To save the changes so they are available after a power fail, refer to Section 5.10.2 on
page 205.
Figure 5-53: SNMP Community Strings Screen
Note: To delete a community string, check the Delete checkbox to the left of
the community string you want to delete and click the button Submit.
Table 5-53: SNMP Community Strings Parameters
Parameter Description
Read Only
[SNMPReadOnlyCommunityString_x]
Up to five read-only community strings (up to 19 characters each).
The default string is ‘public’.
Read / Write
[SNMPReadWriteCommunityString_x]
Up to five read / write community strings (up to 19 characters each).
The default string is ‘private’.
Trap Community String
[SNMPTrapCommunityString]
Community string used in traps (up to 19 characters).
The default string is ‘trapuser’.