User`s manual
MP-1xx/H.323
MP-1xx/H.323 User’s Manual 94 Document #: LTRT-00651
Gateway) or ring signal is applied to FXO Gateway port, refer to Figure 7-18.
Figure 7-18: Automatic Dialing Table
7.2.4.12 Set Up of Caller ID Display Table
“Caller ID Display Info” table, shown in Figure 7-19 contains Caller ID display information per
MP-1xx FXS/FXO Gateway port. This information is sent in H.225 Setup message to remote
party, for Tel % IP calls. Remote party can use this display information for caller identification.
The caller ID string can contain up to 18 characters.
Figure 7-19: Caller ID Table
7.2.4.13 Set Up of Tel to IP Routing Table
“Tel to IP Routing & IP Security” table is needed if the Gateway operates without a Gatekeeper.
It contains up to 50 rows. Each row associates a called phone number prefix with destination IP
address. The routing table can also be used for fallback routing if communication with
Gatekeeper is lost. The IP addresses listed in the table can also be used for security. If security
feature is enabled (SecureCallFromIP = 1) the Gateway will accept calls coming only from these
addresses. The Phone to IP Routing Table is shown in Figure 7-20.