User`s manual

MP-1xx/H.323
MP-1xx/H.323 User’s Manual 78 Document #: LTRT-00651
" Fourth Ring On Time [10 msec] – “Ring Off” period (in 10 msec units) for the forth
cadence on-off cycle.
" Fourth Ring Off Time [10 msec] – “Ring Off” period (in 10 msec units) for the forth
cadence on-off cycle.
" Burst – configures the ringing signal to be a single ringing burst comprised of all specified
above cadences. The “Burst” string is defined per each ringing cadence and it must appear
between “First/Second/Third/Forth” string and the “Ring On/Off Time”.
6.4.3.1 Examples of Various Ringing Signals
#Regular North American Ringing Pattern: 20 Hz, 2 sec On, 4 sec Off
[NUMBER OF DISTINCTIVE RINGING PATTERNS]
Number of Ringing Patterns=1
[Ringing Pattern #0]
Ring Type=0
Freq [Hz]=20
First Ring On Time [10msec]=200
First Ring Off Time [10msec]=400
#GR-506-CORE Ringing Pattern 3: 20 Hz ringing comprised of three cadences
[NUMBER OF DISTINCTIVE RINGING PATTERNS]
Number of Ringing Patterns=1
[Ringing Pattern #0]
Ring Type=0
Freq [Hz]=20
First Ring On Time [10msec]=40
First Ring Off Time [10msec]=20
Second Ring On Time [10msec]=40
Second Ring Off Time [10msec]=20
Third Ring On Time [10msec]=80
Third Ring Off Time [10msec]=400
#EN 300 001 Ring – Finland: informative ringing nr. 3: three ringing bursts followed by repeated ringing of 1
sec on and 3 sec off.
[NUMBER OF DISTINCTIVE RINGING PATTERNS]
Number of Ringing Patterns=1
[Ringing Pattern #0]
Ring Type=0
Freq [Hz]=25
First Burst Ring On Time [10msec]=30
First Burst Ring Off Time [10msec]=30
Second Burst Ring On Time [10msec]=30
Second Burst Ring Off Time [10msec]=30
Third Burst Ring On Time [10msec]=30
Third Burst Ring Off Time [10msec]=30
Fourth Ring On Time [10msec]=100
Fourth Ring Off Time [10msec]=400