Table 6-4: Call Progress Tones Template (continues on pages 74 to 77)
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=0
Second Signal Off Time [10msec]=0
#Dial tone
[CALL PROGRESS TONE #1]
Tone Type=1
Low Freq [Hz]=440
High Freq [Hz]=0
Low Freq Level [-dBm]=10
High Freq Level [-dBm]=32
First Signal On Time [10msec]=300
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=0
Second Signal Off Time [10msec]=0
#Ringback
[CALL PROGRESS TONE #2]
Tone Type=2
Low Freq [Hz]=440
High Freq [Hz]=480
Low Freq Level [-dBm]=19
High Freq Level [-dBm]=19
First Signal On Time [10msec]=0
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=200
Second Signal Off Time [10msec]=400
#Ringback
[CALL PROGRESS TONE #3]
Tone Type=2
Low Freq [Hz]=440
High Freq [Hz]=0
Low Freq Level [-dBm]=16
High Freq Level [-dBm]=32
First Signal On Time [10msec]=0
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=100
Second Signal Off Time [10msec]=300
#Busy
[CALL PROGRESS TONE #4]