Table 6-1: Basic and Logging Parameters (continues on pages 54 to 55)
ini File Field Name
GUI Parameter Name
*
Valid Range and Description
EnableSyslog
(Enable SysLog)
0 = Disable SysLog (default)
1 = Enable SysLog
If SysLog is disabled all Logs and error messages are sent to RS-232
serial port if “DisableRS232 = 0”
DisableRS232
0 – RS-232 serial port is enabled (default)
1 – RS-232 serial port is disabled
To enable sending of all log and error messages to the RS-232 serial port,
define:
“EnableSyslog = 0” and “DisableRS232 = 0”
LoggerFormat
0 – name + msg
1 – time + msg
2 – name + time + msg
3 – SysLog prefix + msg (default)
DisableWebTask
0 – Enable Web management (default)
1 – Disable Web management
ResetWebPassword
Allows resetting to default of Web password to:
Username: “Admin”
Password: “Admin”
Disable WebConfig
0 = Enable changing parameters from Web (default)
1 = Operate Web server in “read only” mode
SNMPManagerIP
(SNMP Manager IP)
IP address of SNMP Manager. The SNMP manager is used for receiving
SNMP Traps.
For example: SNMPManagerIP = 10.2.1.10
DisableSNMP
(Enable SNMP)
0 – SNMP is enabled (default)
1 – SNMP is disabled
HTTPport
HTTP port used for Web management (default = 80)
* The parameter in the brackets refers to the Embedded Web Server. Some parameters don’t