User`s manual
MP-1xx/H.323 User’s Manual 5. Profiling & Operation
Version 4.2 Beta 49 June 2003
3. Start MP-108 Gateway and download the configuration ini file
4. Set default number for NetMeeting to MP-108 calls: DefaultNumber =101 (or any other
number 102 to 108).
5. Start MP-108 Gateway and download the configuration ini file
6. Make a call from any MP-108 end-point to NetMeeting™ by dialing 200
7. Make a call from NetMeeting™ to IP address of MP-108. The phone connected to port 1
of the MP-108 then rings
5.5.4 Remote Extension with FXO & FXS Gateways Example
This application explains how to demonstrate remote extension via IP, using MP-108/FXO and
MP-108/FXS Gateways. In this configuration, PBX incoming calls are routed to “Remote
Extension” via the MP-108/FXO and MP-108/FXS Gateways.
$ Requirements
" One MP-108/FXO Gateway
" One MP-108/FXS Gateway
" Analog phones (POTS)
" PBX – one or more PBX loop start lines
" LAN.
Connect the MP-108/FXO ports directly to PBX lines as shown on the diagram below:
Figure 5-1: MP-108/FXS & MP-108/FXO Layout