User`s manual
MP-1xx/H.323 User’s Manual 4. Software Installation
Version 4.2 Beta 35 June 2003
$ To upgrade the integral Software take the next 5 steps:
1. Start the TFTP and BootP servers, refer to Appendix A.
2. Copy the new ramxxx.cmp file, mp108.ini file (e.g., H323gw.ini) and optional
configuration files to the default TFTP server directory.
3. Set the Boot file and ini file names in the Web browser Network settings page or in the
BootP server: ramxxx.cmp -fb;mp108.ini. Other network parameters stay unchanged (IP
address, subnet mask,…). If so required, it is possible to update only the mp108.ini
parameters. For this option, set the boot file name to: mp108.ini (without preceding
ramxxx.cmp). After MP-1xx power reset, the ini parameters are downloaded using the
TFTP procedure and stored in the non-volatile memory.
4. Reset the MP-1xx. Wait about 20 seconds until the Ready LED changes to Green.
5. After accomplishing BootP and TFTP procedures, the new software is downloaded and
stored in the MP-1xx unit’s flash memory.
Note: The parameter “-fb” added to Boot file name is used to specify the burning of flash
memory with new software image. To test new software version without replacing the
old version, skip the “-fb” parameter. In this case, the new software is downloaded
directly to RAM, and not permanently stored into flash.
4.5.2 Upgrade Procedure Using AudioCodes Configuration Utility
The following procedure describes how to upgrade the MP-1xx software using the AudioCodes
configuration utility.
$ To upgrade the Software using the AudioCodes Configuration Utility
take the next 13 steps:
1. Install AudioCodes’ Configuration utility from the AudioCodes Software CD, Document #
LSTC00005 (MediaPack Series).
2. Open the AudioCodes Configuration utility from Start>Programs>BootP; the
AudioCodes Configuration utility main screen opens:
Figure 4-5: AudioCodes Configuration Utility Main Screen
3. Click on the Edit tab to open the Edit menu.
4. Select Preferences to open Preferences window shown below 36.