User`s manual

MP-1xx/H.323
MP-1xx/H.323 User’s Manual 34 Document #: LTRT-00651
" Templates.
" User-defined names for each entity.
" Protection against entering fault information.
" Unicast or Broadcast BootP response.
4.4.3 Configuring the Windows™ NT DHCP Server
If Microsoft
Windows NT DHCP server is used in your organization, the server can be used in
reservation mode to provide an IP address and other necessary information to the MP-1xx Media
Gateway.
To configure the Microsoft
Windows
NT DHCP Server to assign IP address information to
BootP clients, add a reservation for each BootP client.
For information about how to add a reservation, view the "Managing Client Reservations Help"
topic in DHCP Manager.
The reservation builds an association between the media access control address (12 digits,
provided in MP-1xx documentation) and the IP address. Windows
NT Server provides the IP
address based on the MP-1xx media access control (MAC) address in the BootP request frame.
To configure the Microsoft
Windows
NT DHCP server to provide boot file information to BootP
clients, edit the BootP Table in DHCP Manager. The BootP Table is located in the Server
Properties dialog box that can be accessed from the Server menu. For information about how to
edit the BootP Table, view the "BootP Table" Help topic in DHCP Manager.
The following parameters must be entered:
" Local IP address IP address of your MP-1xx Gateway.
" Subnet mask Refer to Section 4.4 Note 2, for the mask limits.
" Gateway IP address Default Gateway IP address
" Boot File name Optional, refer to following Note.
Note: Boot file name normally should not be used. This field is only used for software upgrade (refer to
Section 4.5.
Refer to Utilities User Manual for detailed description of configuration of Windows NT DHCP
server.
4.4.4 Other TFTP & BootP Servers
Third party TFTP and BootP servers can be used; for example Weird Solutions
(www.weird-
solutions.com).
4.5 MP-1xx Software Upgrade
4.5.1 General Upgrade Procedure
MP-1xx includes on-board flash memory already programmed with application software. The
following procedure replaces the old stored software with the new version. To run this procedure
BootP and TFTP servers are required. Web browser can be used instead of BootP server (refer
to Section 7.2).
Note1: The file extensions cmp and ini should be written in lower case letters.
Note2: When upgrading the internal software (either from a TFTP Server or from the Embedded Web
Server) it is mandatory to download the ram.cmp file and all other related files: ini, coefficient
and call progress tone.