the selected fields from the template. The rest can be unique for each client. When the field is
assigned a value from the selected template, the field is grayed out.
After performing changes, press “Apply” to save them. By clicking on “Apply & Reset”, the
program saves the changes to the database, performs a remote reset to the client by adding the
client’s MAC to the ARP table, and then sends out a reset command. This option works only if
“ARP Manipulation Enabled” checkbox in the “Preferences” window is checked (in Figure 10-2
on page 115) otherwise an error message appears. It requires the User to have administrator
privileges. The remote reset is supported for software in this version and up.
When adding a new client, click on the “Add Client” button; a client with blank parameters is
displayed. After filling out the parameters, click on “Apply”; the client is added.
To find out if there is another BootP server on the net that contains a client with the same MAC
address, click on “Test Selected Clients”; in the log screen, view the IP addresses of all BootP
servers that contain the same MAC address in the status ‘Listed At’. In normal operation, BootP
client MAC address should be listed only on a single BootP server. If the MAC address is listed in
multiple BootP servers, it must be removed from other BootP servers.