User`s manual

MP-1xx/H.323 User’s Manual 8. Diagnostics
Version 4.2 Beta 101 June 2003
4. In the COM1/2 Properties dialog, enter the following settings for the serial
communication port:
Baud Rate: 115,200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow control: Hardware
5. Click OK; the HyperTerminal main screen opens.
After applying power or reset the following information is printed on the terminal screen shown in
Figure 8-2 on page 101. This information can be used to determine possible MP-1xx initialization
problems. Such as incorrectly defined Local IP address, Subnet mask, Default router IP address,
TFTP server IP address, BootFile name, ini file name and Full/Half duplex network state.
Figure 8-2: Status and Error Messages
MAC address = 00-90-8F-01-00-9E
Local IP address = 10.1.37.6
Subnet mask = 255.255.0.0
Default gateway IP address = 10.1.1.5
TFTP server IP address = 10.1.1.167
Boot file name = ram35136.cmp
INI file name = mp108.ini
Call agent IP address = 10.1.1.18
Log server IP address = 0.0.0.0
Full/Half Duplex state = HALF DUPLEX
Flash Software Burning state = OFF
Serial Debug Mode = OFF
Lan Debug Mode = OFF
BootLoad Version 1.75
Starting TFTP download ... Done.
MP108 Version 3.80.00