Installation guide

MP-1xx
MP-1xx 18 Document #: LTRT-61406
¾ To access the CLI via the RS-232 port, take these 2 steps:
1. Connect the MP-1xx RS-232 port to either COM1 or COM2 RS-232 communication port on
your PC with a straight serial cable.
2. Use a serial communication software (e.g., HyperTerminal
TM
) to connect to the MP-1xx.
Set your serial communication software to the following communications port settings:
¾ Baud Rate: 115,200 bps
¾ Data bits: 8
¾ Parity: None
¾ Stop bits: 1
¾ Flow control: Hardware
The CLI prompt is available immediately.
3.1.3.2 Assign an IP Address
¾ To assign an IP address via the CLI, take these 4 steps:
1. At the prompt type ‘conf’ and press enter; the configuration folder is accessed.
2. To check the current network parameters, at the prompt, type ‘GCP IP’ and press enter; the
current network settings are displayed.
3. Change the network settings by typing: ‘SCP IP [ip_address] [subnet_mask]
[default_gateway]’ (e.g., ‘SCP IP 10.13.77.7 255.255.0.0 10.13.0.1’); the new settings take
effect on-the-fly. Connectivity is active at the new IP address.
Note: This command requires you to enter all three network parameters (each separated by
a space).
4. To save the configuration, at the prompt, type ‘SAR’ and press enter; the MP-1xx restarts
with the new network settings.
3.2 Restoring Networking Parameters to their Initial State
You can use the ‘Reset’ button to restore the MP-1xx networking parameters to their factory
default values (described in Table
3-1) and to reset the username and password.
Note that the MP-1xx returns to the software version burned in flash. This process also restores
the MP-1xx parameters to their factory settings. Therefore, you must load your previously
backed-up ini file, or the default ini file (received with the software kit) to set them to their correct
values.
¾ To restore networking parameters to their initial state, take these 6
steps:
1. Disconnect the MP-1xx from the power and network cables.
2. Reconnect the power cable; the gateway is powered up. After approximately 45 seconds the
Ready LED turns to green and the Control LED blinks for about 3 seconds.
3. While the Control LED is blinking, press shortly on the reset button (located on the left side
of the front panel); the gateway resets a second time and is restored with factory default
parameters (username: “Admin”, password: “Admin”).
4. Reconnect the network cable.
5. Assign the MP-1xx IP address (refer to Section
3.1 on page 15).
6. Load your previously backed-up ini file, or the default ini file (received with the software kit).
To load the ini file via the Embedded Web Server, refer to Section
5 on page 27.