User`s manual
MediaPack SIP
MediaPack SIP User’s Manual 284 Document #: LTRT-65405
Table E-7: acBoardEthernetLinkAlarm Alarm Trap
Event Type:
equipmentAlarm
Probable Cause:
underlyingResourceUnavailable (56)
Alarm Text:
Ethernet link alarm: <text>
Status Changes:
Condition: Fault on single interface
Alarm status: major
<text> value: Redundant link is down
Condition: Fault on both interfaces
Alarm status: critical
<text> value: No Ethernet link
Condition: Both interfaces are operational
Alarm status: cleared
Corrective Action: Ensure that both Ethernet cables are plugged into the back of the system. Inspect the
system’s Ethernet link lights to determine which interface is failing. Reconnect the cable
or fix the network problem
E.1.4 Log Traps (Notifications)
This section details traps that are not alarms. These traps are sent with the severity varbind value
of ‘indeterminate’. These traps don’t ‘clear’, they don’t appear in the alarm history or active tables.
One log trap that does send clear is acPerformanceMonitoringThresholdCrossing.
Table E-8: acPerformanceMonitoringThresholdCrossing Log Trap
Alarm:
acPerformanceMonitoringThresholdCrossing
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.27
Default Severity
Indeterminate
Event Type:
other (0)
Probable Cause:
other (0)
Alarm Text:
"Performance: Threshold alarm was set”, with source = name of performance counter
which caused the trap
Status Changes:
Condition: A performance counter has crossed the high threshold
Trap status: Indeterminate
Condition: A performance counter has crossed the low threshold
Trap status: cleared