Table E-5: acBoardOverloadAlarm Alarm Trap
Alarm:
acBoardOverloadAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.11
Default Severity
Major
Event Type:
processingErrorAlarm
Probable Cause:
softwareError (46)
Alarm Text:
Board overload alarm
Status Changes:
Condition: An overload condition exists in one or more of the system components.
Alarm Status: Major
Condition: The overload condition passed
Alarm Status: Cleared
E.1.2 Component: AlarmManager#0
Table E-6: acActiveAlarmTableOverflow Alarm Trap
Alarm:
acActiveAlarmTableOverflow
OID:
1.3.6.1.4.15003.9.10.1.21.2.0.12
Default Severity
Major
Event Type:
processingErrorAlarm
Probable Cause:
resourceAtOrNearingCapacity (43)
Alarm Text:
Active alarm table overflow
Status Changes:
Condition: Too many alarms to fit in the active alarm table
Alarm status: Major
Condition: After raise
Alarm status: Status stays major until reboot. A clear trap is not sent.
Note: The status stays major until reboot as it denotes a possible loss of information until the
next reboot. If an alarm is raised when the table is full, it is possible that the alarm is
active, but does not appear in the active alarm table.
Corrective Action: Some alarm information may have been lost, but the ability of the device to perform its
basic operations has not been impacted. A reboot is the only way to completely clear a
problem with the active alarm table. Contact your first-level group.
E.1.3 Component: EthernetLink#0
This trap relates to the Ethernet Link Module (the #0 numbering doesn’t apply to the physical
Ethernet link).
Table E-7: acBoardEthernetLinkAlarm Alarm Trap
Alarm:
acBoardEthernetLinkAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.10
Default Severity
Critical