User`s manual
MediaPack SIP User’s Manual 17. Selected Technical Specifications
Version 4.6 251 June 2005
Table 17-1: MP-1xx Selected Technical Specifications (continues on pages 249 to 251)
Installation
Desk-top, shelf, or 19-inch rack mount with side brackets.
Electrical
Maximum operating voltage range 90-264 VAC
Nominal operating voltage range 100-250 VAC, 0.5A, 47-63 Hz
Type Approvals
Telecommunication
FCC part 68 & CE CTR21, ASIF S003 (FXS)
Safety and EMC
UL 60950-1, FCC part 15 Class B
CE Mark (EN 60950-1, EN 55022, EN 55024)
Management
Configuration
Gateway configuration using Web browser, CLI or ini files
SNMP v2c
Syslog, per RFC 3164
Local RS-232 terminal
Web Management (via HTTP)
Management and
Maintenance
Telnet
17.2 MP-11x Specifications
Table 17-2: MP-11x Functional Specifications (continues on pages 251 to 253)
Channel Capacity
Available Ports
MP-112R 2 ports*
MP-114 4 ports
MP-118 8 ports
* The MP-112R differs from the MP-114 and MP-118. Its configuration excludes the RS-
232 connector, the Lifeline option and outdoor protection.
MP-11x/FXS Functionality
Short or Long Haul (Automatic Detection):
REN2: Up to 10 km (32,800 feet) using 24 AWG line.
REN5: Up to 3.5 km (11,400 feet) using 24 AWG line.
Note: The lines were tested under the following conditions: ring voltage greater than 30
Vrms, offhook loop current greater than 20 mA (all lines ring simultaneously).
MP-11x includes lightning and high voltage protection for outdoor operation.
The following standards are supported: EN61000-4-5, EN55024 and UL60950.
Caller ID generation: Bellcore GR-30-CORE Type 1 using Bell 202 FSK modulation,
ETSI Type 1, NTT, Denmark, India, Brazil, British and DTMF ETSI CID (ETS 300-659-
1).
Programmable Line Characteristics: Battery feed, line current, hook thresholds, AC
impedance matching, hybrid balance, Tx & Rx frequency response, Tx & Rx Gains.
Programmable ringing signal. Up to three cadences and frequency 15 to 200 Hz.
Drive up to 4 phones per port (total 32 phones) simultaneously in offhook and Ring
states.
MP-11x Ring Equivalent Number (REN) = 5
Over-temperature protection for abnormal situations as shorted lines.
FXS Capabilities
Loop-backs for testing and maintenance.
Additional Features
Polarity Reversal / Wink
Immediate or smooth to prevent erroneous ringing
Metering Tones
12/16 KHz sinusoidal bursts
Distinctive Ringing
By frequency (15-100 Hz) and cadence patterns
Message Waiting Indication
DC voltage generation (TIA/EIA-464-B), V23 FSK data, Stutter dial tone and DTMF
based.