SIP User's Manual I. SNMP Traps
Version 5.0 387 October 2006
I.1.3 Component: EthernetLink#0
The source varbind text for all the alarms under this component is
Board#<n>/EthernetLink#0 where n is the slot number.
This trap relates to the Ethernet Link Module (the #0 numbering doesn’t apply to the
physical Ethernet link). This trap doesn’t apply to TP-260 boards.
Table I-10: acBoardEthernetLinkAlarm Alarm Trap
Alarm:
acBoardEthernetLinkAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.10
Default Severity
Critical
Event Type:
equipmentAlarm
Probable Cause:
underlyingResourceUnavailable (56)
Alarm Text:
Ethernet link alarm: <text>
Status Changes:
Condition:
Fault on single interface
Alarm status: major
<text> value: Redundant link is down
Condition:
Fault on both interfaces
Alarm status: critical
<text> value: No Ethernet link
Condition:
Both interfaces are operational
Alarm status: cleared
Corrective Action:
Ensure that both Ethernet cables are plugged into the back of the system.
Inspect the system’s Ethernet link lights to determine which interface is failing.
Reconnect the cable or fix the network problem